1-2 HP Cycle Timer T1013 120 Volts
[PD2000]
$199.99CAD

The T1013 Cycle Timer a Solid State timer, that has been designed for use with aeroponic and hydroponic systems. This CSA / UL approved unit is rated for inductive loads up to 1/2 HP or 10AMP. On and Off times are separately adjustable from 30 seconds to 1 hour. The T1013 also has a selectable Night - Mode feature that controls the irrigation when your lights are out.

T1013 EQUIPMENT MANUAL

The T1013 Cycle Timer is a full function cycle timer which allows the user to repetitively turn on and off any 120 VAC load device rated at up to 10 Amps or 1/2 Hp. The on and off times are separately adjustable from 30 seconds to 1 hour. The T1013 also has a selectable Night Mode feature. In this mode, instead of taking the off time from the OFF TIME control, the off time becomes a longer preset NIGHT MODE off time whenever ambient light drops below a set level.

Installation:

NOTE: As with all electronic devices, the T1013 should be plugged into a surge protection device to protect it from power line surges.

To install the unit, screw to a wall vertically within reach of a wall socket. Simply plug the load device you wish to switch into the socket on the back of the T1013 piggy back plug. Set the On and Off times, and plug the T1013 Piggy back plug into surge protection device which has been plugged to the 120 volt wall socket. 

The T1013 has no On/Off switch. The units begins to operate in the ON TIME mode as soon as the unit is plugged in.


Operation:

A. Timer Operation

The T1013 is a cycle timer. This means that the unit constantly cycles, or alternates between two modes, an ON TIME mode, and an OFF TIME mode. In the ON TIME mode, the load device is turned on. In the OFF TIME, the load device is turned off.

B. Night Mode Operation 

This mode supplements the basic timer operation. When on, the Timer OFF TIME mode is forced to be an extended 4 hour NIGHT MODE off time no matter what the OFF TIME adjustment is set at. When it is finished, the ON TIME will start again. When this is finished, another NIGHT MODE off time will start.

To enable Night Mode, the Night Mode Switch on the top on the T1013 must be moved to the ON position. The unit will operate as before until the ambient light drops below a set level for more than 15 seconds. If the unit is in the ON TIME Mode the NIGHT MODE off time will start as soon as the present ON TIME finishes. If it is in OFF TIME already, the present OFF TIME will be extended by the NIGHT MODE off time.

The Night Mode off times continue either until the Night Mode switch is turned off, or ambient light raises above the set level for more than 15 seconds. If it is in the off time, it will immediately start to go into ON TIME Mode no matter how much time is left.

The 15 second delay prevents Night Mode being triggered by momentary flashes of light. If you wish to check something, it will allow you to turn on the lights in the darkened room for up to 15 seconds when the unit is in the NIGHT MODE off time, without triggering an immediate ON TIME. 

If you want the T1013 to operate with NIGHT MODE off times all the time regardless of light level, cover the LDR window beside the ON TIME light with a piece of black tape.

C. Controls:

ON TIME KNOB Adjusts the time for which the T1013 will turn on the load device.  This is adjustable from 30 seconds to 1 hour in increments of 15 seconds.  Whenever the load device is turned on, a red light will be on at the top right of the unit.
OFF TIME KNOB Adjusts the time for which the T1013 will turn off the load device.  This is adjustable from 30 seconds to 1 hour in increments of 15 seconds.
NIGHT MODE When the switch is ON, Night Mode is on.  This will give a 4 hour OFFTIME instead of the OFFTIME control knob time when light disappears
LDR This is the clear window next to the ON TIME light.  This is the light level sensor for Night Mode.
This device is a 120 volt North American Style plug on this device.

For more information, please visit this products webpage.
This product was added to our catalog on Wednesday 17 July, 2002.
Reviews
Customers who bought this product also purchased
Black and White Poly Full Roll  1000sq.ft.
Black and White Poly Full Roll 1000sq.ft.
Shopping Cart more
1 x Aeroponic System - Plant Tier PD200
1 x Aeroponic System - Plant Tier V36
$4795.99CAD
Notifications more
NotificationsNotify me of updates to 1-2 HP Cycle Timer T1013 120 Volts
Tell A Friend
 
Tell someone you know about this product.
Reviews more
Write ReviewWrite a review on this product!
Currencies
Information
Official PayPal Seal,and Verify My PayPal Status
I accept payment through PayPal for all Hydroponic and Aeroponic Supplies
  Company   Your Account   Customer Service   Site Map
·
contact us
·
create an account
·
contact us
·
view site map
·
privacy policy
·
login to your account
·
track your order
·
view full catalog
·
terms & conditions
·
forgotten you password?
·
shipping & returns
·
hydroponic books